- Max. 24 ignition outputs
- Triggered by max. 6 pickups (for integration of 2 redundant pickup sets)
- 250 V DC max. primary voltage
- 1000 mJ max. primary energy when firing 24 outputs at 900 rpm (1200 mJ boost for start phase)
- 100 to 1500 μsec max. programmable spark duration
- MOST – MOTORTECH Output Stage Technology
- Available as Heavy Duty (HD) housing version
- Protection class IP65 (HD)
- 18 to 32 V DC supply voltage
- 24 ignition outputs
- 250 V DC primary voltage
- 1000 mJ primary energy (when firing 24 outputs at 900 rpm) 600 mJ primary energy (when firing 24 outputs at 1800 rpm)
- 0.1° crankshaft accuracy
- 6 pickup inputs for integration of 2 redundant pickup sets
- Triggered by 1, 2 or 3 pickups per set (magnetic, Hall effect or inductive/configurable)
- Multiple ignition timing control via
– Speed curve
– 0 to 20 mA analog input
– 0 to10 V analog input - Multiple energy control via MOST (MOTORTECH Output Stage Technology)
- Programmable firing order
- 3 multipurpose outputs (GPO)
- 2 Auxiliary Synchronization Outputs (ASO) which can support a detonation control system (e.g. DetCon) or fuel injection pump controllers
- Ignition release input
- Go/NoGo output
- Overspeed shutdown function
- Access controlled
Downloads
Software
Software Package Firmware Version 1.0.2
Includes firmware version 1.0.2 for hardware 0.03, 0.04, 1.01, 1.03 and 1.04, MICT 2.40.1, MOTORTECH Flash Tool 0.21.00000, drivers 2.12.26 and documentation
MOTORTECH GmbH | Hunaeusstrasse 5 | 29227 Celle Germany | Phone: +49 5141 9399 0 | Send Email